ANALISIS KENAIKAN PLANT HEAT RATE PLTU SEBELUM PERBAIKAN BERKALA TERHADAP KONDISI TESTING KOMISIONING (Studi Kasus : PLTU XX)
DOI:
https://doi.org/10.54378/bt.v16i1.1740Keywords:
heat rate, efficiency, steam, power plantAbstract
Steam power plant is a power plant which use coal as fuel to heating the water into superheated steam. The standard of efficient or not for a power plant can be seen from the value of plant heat rate. Plant heat rate is amount of energy required to generate one kWh electricity. The smallest of that is the best power plant. In general, the value of plant heat rate has increased than commisioning test after the power plant operated continously. The method used in the calculation of the steam power plant is energy balance method. Energy balance calculation method used by the standard of the American Society of Engineers Mechanichal Performance Test Code (ASME PTC). The value of plant heat rate is influenced by the value of turbine heat rate and boiler efficiency from steam power plant. Turbine heat rate is the required energy turbines obtained from heat transfer process to generate one kWh electricity, while boiler efficiency is an indicator from boiler performance of steam power plant by comparing the outputs and inputs. After calculation of plant heat rate at actual condition, the value of plant heat rate has increased than commisioning. The increrase of plant heat rate value is due to more losses which result degradation performance on the main components of the unis, such as : turbine, boiler, air heater and condenser. Therefore necessary corrective maintenance when first year inspection, so that the steam power plant can be re-optimal performance as at commisioning test.
References
American Society of Mechanichal Engineering. 2008. Performance Test Code 4. New York : HIS
American Society of Mechanichal Engineering. 2008. Performance Test Codes 6. New York : HIS
Performance Test Sistem Turbine PLTU Jeranjang Unit 3 1x25 MW, PT Bumi Mitra Adi Persada 2013
Performance Test Sistem Boiler PLTU Jeranjang Unit 3 1x25 MW, PT Bumi Mitra Adi Persada 2013
Pembidangan Pra Jabatan Edisi 1, Suralaya, tahun 2014
Power Plant Enginering Black And Veatch, 2008
Shandong Energy & Architechture Design Institute, Runh Power Plant Enginering Technology co,.LTD, PLTU Nusa Tenggara Barat (Lombok ) 1x25, Tahun 2008
China Changjiang Energy Corp (Group),PLTU Nusa Tenggara Barat (Lombok ) 1x25, 2010
Downloads
Published
Issue
Section
License
Journal Bina Teknika grants open acces to all of its content, based on that matter makes all research papers published are freely available to public which ensures greater global excchange of knowledge
Journal Bina Teknika is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Refers to these license, all research papers agree to the following terms:
- Attribution - Authors holds the credit of their research works published, in order to use materials from one or more research papers published in Bina Teknika should be given appropriate credit
- Non Commercial - All research papers published in Bina Teknika may not use for commercial purposes
- Share Alike - Any creation made under one or more concepts from research papers published in Bina Teknika should be distribute your contributions under the same license as original