ANALISIS WATER BALANCING PRIMARY LOOP CHILLER SYSTEM TERHADAP COP (Coefficient Of Performance)
DOI:
https://doi.org/10.54378/bt.v14i1.257Keywords:
water balancing, Coefficient Of Performance, evaporator, balancing valveAbstract
Water is one of the major media for heat transfer process in the cooling system. The size of the flow rate of water entering the system will affect the overall cooling. Analysis of water balancing primary loop chiller system against COP (Coefficient Of Performance) is based on the observation the performance of the chiller system during operational with temperature of chilled water produced that not able to achieve the desired criteria when demand for chilled water increasing. After analysis conducted, it is known that decreasing efficiency of cooling system caused by uncontrolled water flow rate into the system. After water balancing is done, the flow rate of the water coming into the system (evaporator) can be controlled by using the balancing valve so that the flow rate increased from 16.07 x 10-3 m3 / s to 52.70 x 10-3 m3 / s, resulting in increased chiller COP value system from 2.4 to 4.1.
References
ASHRAE “Handbook Fundamental”, American Society of Heating Refrigerating and Air Conditioning Engineers, Atlanta, GA. 1985.
Avery, G. “Improving the efficiency of chilled water plants”. ASHRAE Jurnal 43(5): 14-18. 2001.
D. Holder MSME, Roger. “Balancing of a Water and Air System”. ASHRAE Jurnal 37. 2003.
Durkin, Thomas H. November. “Evolving Design of Chiller Plant”. ASHRAE Jurnal 47: 11: 40-50. 2005.
Gumilar, Arie. “Sistem air Pendingin”. Jakarta: STE, 2011.
Herbert W. Stanford : “HVAC Water Chillers and Cooling Towers. CRC Press, 2ndedition”, April 2016.
ITT Fluid Technology Corporation. “Large Chilled Water Systems Design Workshop Manual”. 1996.
Keister, Timothy.“Cooling Water Management Basic Principles and Technology”. New York: ProChemTech International, 2008.
Shan K. Wang: “Handbook of Air Conditioning and Refrigeration, 2ndedition”. McGraw-Hill Professional, 2001.
Stocker. W.F, Jernold. W.J., “Refrigerasi dan Pengkondisian Udara, edisi ke-2”, Erlangga, Jakarta, 1989.
Stoecker, Wilbert F., and Jones, Jerold W. “Refrigerasi dan Pengkondisian Udara”. Jakarta : Erlangga, 1982.
Downloads
Published
Issue
Section
License
Journal Bina Teknika grants open acces to all of its content, based on that matter makes all research papers published are freely available to public which ensures greater global excchange of knowledge
Journal Bina Teknika is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.
Refers to these license, all research papers agree to the following terms:
- Attribution - Authors holds the credit of their research works published, in order to use materials from one or more research papers published in Bina Teknika should be given appropriate credit
- Non Commercial - All research papers published in Bina Teknika may not use for commercial purposes
- Share Alike - Any creation made under one or more concepts from research papers published in Bina Teknika should be distribute your contributions under the same license as original